The clamp-on design is not necessary to shut down flow or cut the pipe when installing the Ultrasonic Flow Meter.
Ambient Temperature: Converter: -20°C ~ 60°C; Transducer: -30°C ~ 90°C
Installation: Clamp-on
Measure Principles: Time Transit
Flow Range: ± 0.03 m/s ~ 12 m/s
Accuracy: ± 2%
Response Time: < 1 Sec.
Resolution: 0.0001 m/s
Digital Output: RS-485 (Modbus RTU), Pulse (Forward)
Communications Distance: 1000 m
Analogue Output: 4-20mA
Measurement Temp. Range: 30°C ~ 90°C
Unit: Metric / Imperial
Power: AC 100V ~ 240V
Display: English, 128 x 64 LCD
Operation: 4 buttons
Safety: Lockable keypad, offline data protection
Case: ABS
Size: 145 x 90 x 45 (mm)
ENHANCED MEASURING PERFORMANCE
US Ultrasonic flow meter provides sensitive transducers that operate at various frequencies that match the acoustic properties of the pipes. This proprietary design allows for strong and stable flow measurement signals and minimizes the effect of noise.
EASILY MOUNTABLE ON EXISTING PIPE
Install the US Ultrasonic flow meter in existing systems at any time without disrupting flow.
HIGHLY ACURATE OVER A WIDE FLOW RANGE
±2% of reading flow measurement accuracy from 0.03 m/sec to 12 m/sec velocity. Matched transducers and a built-in auto zero function ensure excellent low flow performance.
SIMPLIFIED INSTALLATION AND COMMISIONING
Each ultrasonic flow meter is fully calibrated and programmed before it leaves the factory.
APPLICABLE FLUIDS
Tap water / Potable water / Cooling water / Hot water / Sea water / Raw water / Plant oil.
COMMUNICATIONS
The US Ultrasonic flow meter provided with Modbus RTU networks, RS-485, 4-20mA and pulse connection.
SENSOR INSTALLATION
Transducers should be installed by different ways (Type: V and Z) based on the size of the pipes.